Control Room Operator

Competency-based
ONET: 51-8012.00

2

Years

70

Skills

235h

Related instructions
Curriculum
  • Performing Start-Up, Trip Recovery, Plant Controls and Signal Diagrams
  • Performing Normal Operations on Start-Up, Shut-Down, and Trip Recovery
  • Performing Trip Recovery and Malfunctions Response
  • Responding to Major Malfunctions and Performing Start-Up and Recovery
  • Supporting Apprentices Through On-The-Job Training
  • Final Exam and Review
  • Performing Start-Up, Trip Recovery, Plant Controls & Signal Diagrams Simulator Time
On-the-job training
  • Performing Startup, Trip Recovery, Plant Controls and Signal Diagrams
    • Lock open the boiler feed pump recirculation valves
    • Operate the Unit 3 steam face coils to put in service and lock down
    • Operate the drum level control manually
    • Admit seal steam to G-Heater
    • Start the submerged flight conveyor on Unit 3
    • Start the economizer on lower dry flight on Unit 3
    • Start the economizer on upper dry flight on Unit 3
    • Start the SCR on lower dry flight on Unit 2
    • Start the SCR on upper dry flight on Unit 2
    • Start up at farm on the ammonia system on Unit 2
    • Start the start-up boiler feed pump
    • Start a main condenser hotwell pump with no pumps running
    • Start a main condenser hotwell pump with one pump running
    • Start a second boiler feed pump turbine
    • Adjust air flow to influence re-heat temperature
    • Start an air heater
    • Start an induced draft fan
    • Start a forced draft fan
    • Purge the boiler
    • Start a primary air fan
    • Start an electrical hydraulic control pump
    • Calculate maximum allowable top to bottom drum metal temperature differential
    • Blow soot in the boiler
    • Establish turbine rotor pre-warm
    • Activate the wobulator
    • Apply steam seals to the turbine and pull vacuum on the main condenser
  • Performing Normal Operations on Start-Up, Shut-Down, and Trip Recovery
    • Establish light off air flow on a individual mill package
    • Increase the bias on B pulverizer group
    • Start a set of gas lighters
    • Automate an pulverizer mill package
    • Fill the cooling tower basin
    • Fill the circulating water tunnels
    • Start a cooling tower fan
    • Start a circulating water pump
    • Automate the boiler master
    • Automate the fuel master
    • Place the stator cooling water system in service
    • Test the main control valves
  • Performing Trip Recovery and Malfunctions Response
    • Perform an emergency stop on a pulverizer mill package
    • Demonstrate the response to high pulverizer mill differential pressure
    • Demonstrate the response to a coal feeder trip
    • Demonstrate the response to a pulverizer fire
    • Automate the super heat spray controls
    • Automate the reheat spray controls
    • Place the turbine on turning gear
    • Calculate the correct acceleration rate for the turbine using the turbine starting and loading instructions
    • Synchronize the generator and close the main generator breaker
    • Calculate maximum allowable VAR load for a given megawatt load using the generator capability curve
    • Increase generator terminal voltage
    • Operate the unit in boiler follow mode
    • Operate the unit in turbine follow mode
    • Operate the unit in megawatt control with boiler follow mode
  • Responding to Major Malfunctions and Performing Start-Up and Recovery
    • Bypass feed water flow around a high pressure heater (Simulator)
    • Demonstrate the response to a deaerator high level trip (Simulator)
    • Demonstrate the respond to a boiler feed pump turbine trip (Simulator)
    • Demonstrate the response to a forced draft fan trip (Simulator)
    • Demonstrate the response to an induced draft fan trip (Simulator)
    • Demonstrate the response to a circulation pump trip (Simulator)
    • Demonstrate the response to a scrubber booster fan trip (Simulator)
    • Properly operate the turbine with A heater out of service
    • Demonstrate the proper response to a turbine trip
    • Demonstrate the proper response to a boiler trip
    • Establish normal back-feed for the in-house electrical distribution system
    • Perform deicing on a cooling tower
  • Maintaining Safe Work Practices with Breakers and Arc Flash
    • Maintain safe work practices
    • Identify the OSHA requirements to protect against electrical and arc hazards
    • Identify low voltage circuit breakers, circuit breakers and motors
  • Supporting Apprentices through On-the-job training
    • Identify DOL regulations and Labor Agreement for journeymen working with apprentices
    • Conduct pre-job briefing
    • Communicate effectively with apprentices