East Energy Renewables, LLC
Control Room Operator
Competency-based
ONET: 51-8012.00
2
Years
70
Skills
235h
Related instructions
Curriculum
Performing Start-Up, Trip Recovery, Plant Controls and Signal Diagrams
Performing Normal Operations on Start-Up, Shut-Down, and Trip Recovery
Performing Trip Recovery and Malfunctions Response
Responding to Major Malfunctions and Performing Start-Up and Recovery
Supporting Apprentices Through On-The-Job Training
Final Exam and Review
Performing Start-Up, Trip Recovery, Plant Controls & Signal Diagrams Simulator Time
On-the-job training
Performing Startup, Trip Recovery, Plant Controls and Signal Diagrams
Lock open the boiler feed pump recirculation valves
Operate the Unit 3 steam face coils to put in service and lock down
Operate the drum level control manually
Admit seal steam to G-Heater
Start the submerged flight conveyor on Unit 3
Start the economizer on lower dry flight on Unit 3
Start the economizer on upper dry flight on Unit 3
Start the SCR on lower dry flight on Unit 2
Start the SCR on upper dry flight on Unit 2
Start up at farm on the ammonia system on Unit 2
Start the start-up boiler feed pump
Start a main condenser hotwell pump with no pumps running
Start a main condenser hotwell pump with one pump running
Start a second boiler feed pump turbine
Adjust air flow to influence re-heat temperature
Start an air heater
Start an induced draft fan
Start a forced draft fan
Purge the boiler
Start a primary air fan
Start an electrical hydraulic control pump
Calculate maximum allowable top to bottom drum metal temperature differential
Blow soot in the boiler
Establish turbine rotor pre-warm
Activate the wobulator
Apply steam seals to the turbine and pull vacuum on the main condenser
Performing Normal Operations on Start-Up, Shut-Down, and Trip Recovery
Establish light off air flow on a individual mill package
Increase the bias on B pulverizer group
Start a set of gas lighters
Automate an pulverizer mill package
Fill the cooling tower basin
Fill the circulating water tunnels
Start a cooling tower fan
Start a circulating water pump
Automate the boiler master
Automate the fuel master
Place the stator cooling water system in service
Test the main control valves
Performing Trip Recovery and Malfunctions Response
Perform an emergency stop on a pulverizer mill package
Demonstrate the response to high pulverizer mill differential pressure
Demonstrate the response to a coal feeder trip
Demonstrate the response to a pulverizer fire
Automate the super heat spray controls
Automate the reheat spray controls
Place the turbine on turning gear
Calculate the correct acceleration rate for the turbine using the turbine starting and loading instructions
Synchronize the generator and close the main generator breaker
Calculate maximum allowable VAR load for a given megawatt load using the generator capability curve
Increase generator terminal voltage
Operate the unit in boiler follow mode
Operate the unit in turbine follow mode
Operate the unit in megawatt control with boiler follow mode
Responding to Major Malfunctions and Performing Start-Up and Recovery
Bypass feed water flow around a high pressure heater (Simulator)
Demonstrate the response to a deaerator high level trip (Simulator)
Demonstrate the respond to a boiler feed pump turbine trip (Simulator)
Demonstrate the response to a forced draft fan trip (Simulator)
Demonstrate the response to an induced draft fan trip (Simulator)
Demonstrate the response to a circulation pump trip (Simulator)
Demonstrate the response to a scrubber booster fan trip (Simulator)
Properly operate the turbine with A heater out of service
Demonstrate the proper response to a turbine trip
Demonstrate the proper response to a boiler trip
Establish normal back-feed for the in-house electrical distribution system
Perform deicing on a cooling tower
Maintaining Safe Work Practices with Breakers and Arc Flash
Maintain safe work practices
Identify the OSHA requirements to protect against electrical and arc hazards
Identify low voltage circuit breakers, circuit breakers and motors
Supporting Apprentices through On-the-job training
Identify DOL regulations and Labor Agreement for journeymen working with apprentices
Conduct pre-job briefing
Communicate effectively with apprentices
Interested in this apprenticeship?
Sign up to receive notifications about changes and updates about Control Room Operator
Keep me notified
Program
East Energy Renewables, LLC
Headquarters location
Farmville, NC (27828)
State
North Carolina
FIND APPRENTICESHIPS BY STATE
Alabama
Alaska
American Samoa
Arizona
Arkansas
California
Colorado
Connecticut
Delaware
Florida
Georgia
Guam
Hawaii
Idaho
Illinois
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi
Missouri
Montana
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
North Carolina
North Dakota
Northern Mariana Islands
Ohio
Oklahoma
Oregon
Pennsylvania
Puerto Rico
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Utah
Vermont
Virginia
Virgin Islands
Washington
Washington D.C.
West Virginia
Wisconsin
Wyoming